Tel:+86-755-26890807
    ? Email:export@
    Product Details
    Home / Products / Clinical Instrument / HbA1c / GSH-60

    loading

    GSH-60

    Automatic HPLC HbA1c Analyzer.
    • Goldsite

    Availability:

    1



    DESIGN FOR EFFICIENCY AND PRECISION

    Up to 60 tests per hour. STAT position supported



    2



    EXCELLENT PRECISION: CV<1.5%

    JCTLM reference measurement method- ion exchange high performance liquid chromatography (HPLC)

    The GSH-60 HbA1c Analyzer offers three specialized modes—Normal Mode for routine HbA1c testing, Variant Mode for enhanced detection of hemoglobin variants (e.g., HbS, HbC, HbE), and Thalassemia Mode for precise quantification of HbA2, HbF, and HbA1c—ensuring accurate and tailored diagnostics for diverse clinical needs.


    PERFORMANCE COMPARISON: GSH-60 VS.Tosoh HLC -723G8

    3



    SELF-DEVELOPED CONSUMABLES AND REAGENTS

    Excellent performance and stable quality

    Highly reusable chromatographic columns and filters

    Comprehensive quality control system for reagents

    Compatible quality control products and calibrators


    Cat No. Description Pack Size  Unit
    1 Reagent Kit   (350 Tests)


    GH1800 HbA1c   Elution Buffer A 800 mL 1
    GH2400 HbA1c   Elution Buffer B 400 mL 1
    GH3400 HbA1c   Elution Buffer C 400 mL 1
    GHL2000 Hemolysis 2000 mL 2
    GH001 Filter 1 2
    2 Column


    GH091 Test   Column  1 (10K test)  1

    3 Calibrator &   Control
    HBBZGH HbA1c   Calibrator 2*0.5mL 1
    HBDM072 HbA1c   Control 0.5mL 1
    HBDM072H HbA1c   Control High Level 0.5mL 1



    3 Performance


    • Excellent precision: CV≤1.5%

    • Broader test range: 2.8%~18.4%

    • Report multiple glycation components to provide more comprehensive clinical reference

    • Versatile Analytical Modes: Normal Mode, Variant Mode, Thalassemia Mode.


    1 Easy Maintenance


    • Automated daily maintenance

    • Power-saving auto Stand-by function

    • Utilize 4~12 Mpa high pressure pump which offers steady output and minimizes pipe blockage


    2 High Efficiency


    • Up to 60 tests per hour. STAT position supported.

    • Direct whole blood testing

    • Cap piercing and no sample pre-treatment

    • 110 sample positions with automatic loading function.

    • Automatic identification of sample tube type.

    • Userfriendly 20° flippable touch screen






    Prevention and monitoring of chronic

    complications of diabetes mellitus

    Differentiation

    of stress hyperglycemia

    from diabetes mellitus

    Diagnosis of neonatal and gestational diabetes mellitus

    Early screening and diagnosis of diabetes mellitus

    Evaluation of the effectiveness of blood glucose control programs

    The American Diabetes Association (ADA) recommends

    HbA1c Recommended Testing Frequency:

    At least twice a year in patients with stable and satisfactorily controlled blood glucose


    • For those with unsatisfactory blood glucose control and need to adjust their regimen, testing should be done once every 3 months or so

    • For pregnant women with diabetes mellitus treated with insulin, a test once every 2 months is recommended.

    • For women with diabetes who are planning to become pregnant, glycosylated hemoglobin should be measured once a month at the beginning;After the blood sugar control is satisfactory, the test can be changed to once every 6-8 weeks until conception.


    *Product images are for illustrative purposes only and may differ from the actual product.  Goldsite Diagnostics Inc. reserves the right to change the packaging design at anytime.

    See Goldsite's latest trend on social media.

    Goldsite Diagnostics Inc., founded in 1999, is a leading Chinese diagnostics manufacturer specializing in in-vitro diagnostics devices and reagents.

    Quick Links

    Product Links

    Get in touch

    ?    (+86)-755-26890807

            (+86)-755-26897973
    ?   export@

    ?

    Copyright ? 1999- 2023 Goldsite Diagnostics Inc., All rights reserved.  Sitemap